Showing 25–34 of 34 results
-
Intel Elec Bracket Mtd Gauge Pressure Transmitte IGP20: Measures Pressure And Transmits A Proportional Electrical Signal In Either Analog Or Digital Mode. T: Intelligent; Digital HART & 4 To 20 mA 22: 316 ss Hi-Side Cover, 316L ss Sensor, Silicone Fill Fluid B: 0.87 And 50 kPa, 3.5 And 200 inH2O, 8.7 And 500 mbar 0: None, Connect Directly To Process Cover 1: 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing F: FM Intrinsically Safe For Class I, Division 1, Groups A, B, C, & D; Class II, Division 1, Groups E,F, & G; And Class III, Division 1. Also Class I, Division 2, Groups A,B,C, & D; Class II, Groups F & G; And Class III, Division 2. Explosionproof For Class I, Division 1, Groups B,C, & D; Dust-Ignitionproof For Class II, Division 1, Groups E,F,G; And Class III, Div 1. Zone Certified Intrinsically Safe AEx ia H1: Manifold Attachment and Leak Tested T: Supplemental Customer Tag Tags Instrument Tag BLANK Calibrated Range 0 – 560 mmH2O
Foxboro
-
Intel Elec d/p Cell Transmitter IDP10- Measures The Difference Between Two Pressures And Transmits A Proportional Or Square Root (Flow) Electrical Signal. T- Intelligent; Digital HART & 4 To 20 mA 22- 316 ss Process Cover, 316L ss Sensor, Silicone Fill Fluid A- 0.12 And 7.5 kPa, 0.5 And 30 inH2O, 1.2 And 75 mbar 2- 1/2 NPT 1- 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing F- FM Intrinsically Safe For Class I, Division 1, Groups A, B, C, & D; Class II, Division 1, Groups E,F, & G; And Class III, Division 1. Also Class I, Division 2, Groups A,B,C, & D; Class II, Groups F & G; And Class III, Division 2. Explosionproof For Class I, Division 1, Groups B,C, & D; Dust-Ignitionproof For Class II, Division 1, Groups E,F,G; And Class III, Div 1. Zone Certified Intrinsically Safe AEx ia IIC And AEx n IIC. T- Supplemental Tag Tags Instrument Tag BLANK Calibrated Range 0 – 661 mmH2O
Foxboro
-
Intel Elec d/p Cell Transmitter IDP10: Measures The Difference Between Two Pressures And Transmits A Proportional Or Square Root (Flow) Electrical Signal T: Intelligent; Digital HART & 4 To 20 mA 22: 316 ss Process Cover, 316L ss Sensor, Silicone Fill Fluid C: 7 And 210 kPa, 28 And 840 inH2O, 70 And 2100 mbar 2: 1/2 NPT 1: 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing F: FM Intrinsically Safe For Class I, Division 1, Groups A, B, C, & D; Class II, Division 1, Groups E,F, & G; And Class III, Division 1. Also Class I, Division 2, Groups A,B,C, & D; Class II, Groups F & G; And Class III, Division 2. Explosionproof For Class I, Division 1, Groups B,C, & D; Dust-Ignitionproof For Class II, Division 1, Groups E,F,G; And Class III, Div 1. Zone Certified Intrinsically Safe AEx ia IIC And AEx n II T: Supplemental Tag Tags Instrument Tag BLANK Calibrated Range 0 – 6350 mmH2O
Foxboro
-
Intel Elec d/p Cell Transmitter IDP10: Measures The Difference Between Two Pressures And Transmits A Proportional Or Square Root (Flow) Electrical Signal. T: Intelligent; Digital HART & 4 To 20 mA 22: 316 ss Process Cover, 316L ss Sensor, Silicone Fill Fluid B: 0.87 And 50 kPa, 3.5 And 200 inH2O, 8.7 And 500 mbar 2: 1/2 NPT 1: 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing F: FM Intrinsically Safe For Class I, Division 1, Groups A, B, C, & D; Class II, Division 1, Groups E,F, & G; And Class III, Division 1. Also Class I, Division 2, Groups A,B,C, & D; Class II, Groups F & G; And Class III, Division 2. Explosionproof For Class I, Division 1, Groups B,C, & D; Dust-Ignitionproof For Class II, Division 1, Groups E,F,G; And Class III, Div 1. Zone Certified Intrinsically Safe AEx ia IIC And AEx n T: Supplemental Tag Tags Instrument Tag BLANK Calibrated Range 0 – 1334 mmH2O
Foxboro
-
Intel Elec d/p Cell Transmitter IDP10: Measures The Difference Between Two Pressures AndTransmits A Proportional Or Square Root (Flow) ElectricalSignal.T: Intelligent; Digital HART & 4 To 20 mA22: 316 ss Process Cover, 316L ss Sensor, Silicone Fill FluidB: 0.87 And 50 kPa, 3.5 And 200 inH2O, 8.7 And 500 mbar0: No Connectors, Both Covers Tapped For 1/4 NPT 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing FM Intrinsically Safe For Class I, Division 1, Groups A, B, C,& D; Class II, Division 1, Groups E,F, & G; And Class III,Division 1. Also Class I, Division 2, Groups A,B,C, & D; ClassII, Groups F & G; And Class III, Division 2. Explosionproof ForClass I, Division 1, Groups B,C, & D; Dust-Ignitionproof For II, Division 1, Groups E,F,G; And Class III, Div 1. ZoneCertified IM1: Painted Steel Mounting Bracket WitL1: Digital Indicator, Internal Pushbuttons, And Window CoverH1: Manifold Attachment and Leak TestedT: Supplemental TagTags Instrument Tag BLANK Calibrated Range 0 – 1334 mmH2O
Foxboro
-
Intel Elec d/p Cell Transmitter T: Intelligent; Digital HART & 4 To 20 mA 22: 316 ss Process Cover, 316L ss Sensor, Silicone Fill Fluid C: 7 And 210 kPa, 28 And 840 inH2O, 70 And 2100 mbar 0: No Connectors, Both Covers Tapped For 1/4 NPT 1: 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing F: FM Intrinsically Safe For Class I, Division 1, Groups A, B, C, & D; Class II, Division 1, Groups E,F, & G; And Class III, Division 1. Also Class I, Division 2, Groups A,B,C, & D; Class II, Groups F & G; And Class III, Division 2. Explosionproof For Class I, Division 1, Groups B,C, & D; Dust-Ignitionproof For Class II, Division 1, Groups E,F,G; And Class III, Div 1. Zone Certified Intrinsically Safe AEx ia IIC And AEx n IIC. M1: Painted Steel Mounting Bracket With Plated Steel Bolts L1: Digital Indicator, Internal Pushbuttons, And Window Cover H1: Manifold Attachment and Leak Tested T: Supplemental Tag Tags Instrument Tag BLANK Calibrated Range 0 – 20320 mmH2O
Foxboro
-
Intel Elec Direct Conn Gauge Pressure Transmitter IGP10: Measures Pressure And Transmits A Proportional Electrical Signal. T: Intelligent; Digital HART & 4 To 20 mA 22: 316L ss Process Connection, 316L ss Diaphragm, Silicone Fill Fluid, 1/2 NPT External & 1/4 NPT Internal Thread Connection Type D: 0.07 & 2.1 MPa, 10 & 300 psi, 0.70 & 21 bar or kg/cm² 1: 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing F: FM Intrinsically Safe For Class I, Division 1, Groups A, B, C, & D; Class II, Division 1, Groups E,F, & G; And Class III, Division 1. Also Class I, Division 2, Groups A,B,C, & D; Class II, Groups F & G; And Class III, Division 2. Explosionproof For Class I, Division 1, Groups B,C, & D; Dust-Ignitionproof For Class II, Division 1, Groups E,F,G; And Class III, Div 1. Zone Certified Intrinsically Safe AEx ia IIC And AEx n IIC. H1: Manifold Attachment and Leak Tested T: Supplemental Customer Tag Tags Instrument Tag BLANK Calibrated Range 0 – 10ba
Foxboro
-
Intel Elec Direct Conn Gauge Pressure Transmitter IGP10: Measures Pressure And Transmits A Proportional Electrical Signal. T: Intelligent; Digital HART & 4 To 20 mA 22: 316L ss Process Connection, 316L ss Diaphragm, Silicone Fill Fluid, 1/2 NPT External & 1/4 NPT Internal Thread Connection Type E: 0.70 & 21 MPa, 100 & 3000 psi, 7.0 & 210 bar or kg/cm² 1: 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing F: FM Intrinsically Safe For Class I, Division 1, Groups A, B, C, & D; Class II, Division 1, Groups E,F, & G; And Class III, Division 1. Also Class I, Division 2, Groups A,B,C, & D; Class II, Groups F & G; And Class III, Division 2. Explosionproof For Class I, Division 1, Groups B,C, & D; Dust-Ignitionproof For Class II, Division 1, Groups E,F,G; And Class III, Div 1. Zone Certified Intrinsically Safe AEx ia IIC And AEx n IIC. H1: Manifold Attachment and Leak Tested T: Supplemental Customer Tag Tags Instrument Tag BLANK Calibrated Range 0-170bar
Foxboro
-
Intel Elec Direct Conn Gauge Pressure Transmitter IGP10: Measures Pressure And Transmits A Proportional Electrical Signal. T:Intelligent; Digital HART & 4 To 20 mA 22: 316L ss Process Connection, 316L ss Diaphragm, Silicone Fill Fluid, 1/2 NPT External & 1/4 NPT Internal Thread Connection Type F: 14 & 42 MPa, 2000 & 6000 psi, 140 & 420 bar or kg/cm² 1: 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing F: FM Intrinsically Safe For Class I, Division 1, Groups A, B, C, & D; Class II, Division 1, Groups E,F, & G; And Class III, Division 1. Also Class I, Division 2, Groups A,B,C, & D; Class II, Groups F & G; And Class III, Division 2. Explosionproof For Class I, Division 1, Groups B,C, & D; Dust-Ignitionproof For Class II, Division 1, Groups E,F,G; And Class III, Div 1. Zone Certified Intrinsically Safe AEx ia IIC And AEx n IIC. H1: Manifold Attachment and Leak Tested T: Supplemental Customer Tag Tags Instrument Tag BLANK Calibrated Range 0 – 270 bar
Foxboro
-